Application Note: NIS Devices configuration

From nemeuswiki
Revision as of 17:36, 11 January 2019 by Lcs (talk | contribs)
Jump to: navigation, search


1 Configuration with Nemeus USB stick

Most of Nemeus devices can be reconfigured thanks to Nemeus USB stick and MM002 Java application.

In addition of the Java application and the USB stick, it needs Yaml File for the device configuration.



2 Usage

Open "LoRa device config" in config Menu. The following display will show up :

Device configuration windows

The "devUid" field must be filled up with the device Uid of the device to be configured.

The "Authentication Key" field must be filled up with the AppSKey of the device to be configured.


2.1 Reading device

When ready, user should set the device in "Test mode" as explained in the wiki (e.g. Test mode for NIS-TR ). Then if you press "Read Device" button the following window should pop up.

Device configuration windows for pt100

This is an example for NIS TR product. If the window did not show up, please verify the following point:

 - device to be read is set in "Test mode" (Led of the device should blink regularly)
 - correct devUid and AppSKey has been entered. Please note that the key is the AppSKey and not the AppKey

2.2 Writing device

Just push to the Write Dev button.
If the device has been disconnected from Test Mode you just need to put it again in Test mode and write the device (you don't need to read it again).

2.3 Applying new configuration

Depending on the parameters, the configuration could be used directly or you might need to restart the device, To do so

 -a) remove, insert battery
 -b) Set the magnet around 20 seconds (until it stop blinking and then remove it immediatly) 

After restart you may need to set the device back to IDLE mode, A join will be performed by LoRaWan device.


2.4 Device parameters

2.4.1 Device sensor/application parameters

2.4.2 Device network parameters