Revision as of 10:21, 14 December 2017 by Lcs (talk | contribs) (Created page with "Category:MM002 Category:Modules == Sigfox Pre-certification == === Test mode for qualification === Stack must be activated via: AT+SF=ON ==== Uplink test mode...")
Contents
1 Sigfox Pre-certification
1.1 Test mode for qualification
Stack must be activated via:
AT+SF=ON
1.1.1 Uplink test mode
TST modem must have uplink and download test mode activated by the the following commands.
Cmd : AT$ST=[<count>,<period>,<channel>]<CR> : to activate the test mode :
Resp:
OK<CR>(<LF: optional>)
- count = 0..32767 or -1 : infinite loop sending user frames (count * burst of 3 frames) : default value : 10
- period = 1..255 seconds for sending test frame every period seconds : default value : 1
- channel = 0..480 or -1 : hopping activ
1.1.2 Downlink test mode
Cmd : AT$SR=<seq_number>,<channel>,<count><CR> : to activate the rx test mode :
- <seq_number> = seq number to receive permanently
- <count> = number of frame to receive 0 or 1: permanently reception.
- <channel> = 0..480 : channel arround reception center frequency where to receive
Resp :
RX=<message1><CR>(<LF: optional>) RSSI=<rssi_value for message 1><CR>(<LF: optional>) RX=<message2><CR>(<LF: optional>) RSSI=<rssi_value for message 2><CR>(<LF: optional>) …. RX=<message n><CR>(<LF: optional>) RSSI=<rssi_value for message n><CR>(<LF: optional>)
1.1.3 Continuous wave
To run radiated tests for SIGFOX classification, continuous wave is needed (without any modulation).
Cmd : AT$CW=<frequency>,<mode>,{<optional power>} <CR>
- <frequency> = center frequency for carrier
- <mode>= 0: off 1 : on
- <power>= value in dBm optional . If power is max power = 14dBm (used for SIGFOX tests) : no need to specify it in AT command parameter.
Note: This command is mandatory for certification of your device for CE.
Resp :