1 LoRaWan Mode

1.1 Sensors stuck on SF12 datarate since the join procedure

The first data transmitted is always with SF12. This is to be compatible with most network architectures. For example, you can perform a join in SF10 but there is no guarantee that you will be able to communicate with the same SF.

The Network Server should use Adaptive Data Rate (ADR) mechanism to lower the SF.

If the device is stuck in SF12 despite good radio conditions (for example, in line of sight) it means that the Network Server does not manage ADR.



2 Sigfox Mode

2.1 Link quality

Sigofx deliver Link Quality information as explained in link-quality:-general-knowledge page.

A device can toggle between two level quality depending on RSSI and number of stations reached which are two parameters that can fluctuate in time. For example:

- a device around -122dBm will likely fluctuate between GOOD and EXCELLENT. 
- a device around -135dBm will likely fluctuate between AVERAGE and LIMIT. PLease Note also that with this quality Link LIMIT trames might be lost. The floor level detection of Sigfox is around -138 dBm