(Created page with "Category:Sensors === Sensors stuck on SF12 datarate since the join procedure === The first data transmitted is always with SF12. This is to comply with most kind of...")
 
Line 8: Line 8:
 
=== Sensors stuck on SF12 datarate since the join procedure ===
 
=== Sensors stuck on SF12 datarate since the join procedure ===
  
The first data transmitted is always with SF12. This is to comply with most kind of network architecture.
+
The first data transmitted is always with SF12. This is to be compatible with most network architectures.
For example you can perform a join with SF10 but it's not guarantee that you could communicate with same SF.
+
For example, you can perform a join in SF10 but there is no guarantee that you will be able to communicate with the same SF.
  
The Network Server should use ADR mechanism to lower the SF.
+
The Network Server should use Adaptive Data Rate (ADR) mechanism to lower the SF.
  
If the device is stuck at SF12 with good radio condition it means that the NS do not manage ADR
+
If the device is stuck in SF12 despite good radio conditions (for example, in line of sight) it means that the Network Server does not manage ADR.

Revision as of 11:08, 28 November 2017




Sensors stuck on SF12 datarate since the join procedure

The first data transmitted is always with SF12. This is to be compatible with most network architectures. For example, you can perform a join in SF10 but there is no guarantee that you will be able to communicate with the same SF.

The Network Server should use Adaptive Data Rate (ADR) mechanism to lower the SF.

If the device is stuck in SF12 despite good radio conditions (for example, in line of sight) it means that the Network Server does not manage ADR.