Difference between revisions of "NIS-UL UltraSonic Sensor"
m (→Ultrasonic sensor properties) |
m |
||
Line 34: | Line 34: | ||
== Uplink data Frame format == | == Uplink data Frame format == | ||
+ | <span style="color:#FF0000">'''Note :''' Frame format of sensors delivered before 1st of November 2017 can be found [[NIS-UL UltraSonic Sensor - Frame Format v0.x|here]] </span> | ||
+ | <br><br> | ||
The uplink payload contains multiple fields: | The uplink payload contains multiple fields: | ||
<mask>: bit field on 1 byte indicating the presence of other fields. Bit 7 is always to 1 because the mask is never extended on next byte. Least significant bit (bit 0) indicates the presence of <usonic_dist> field, bit 1 indicates the presence of <voltage>, bit 2 indicates the presence of <temp>. | <mask>: bit field on 1 byte indicating the presence of other fields. Bit 7 is always to 1 because the mask is never extended on next byte. Least significant bit (bit 0) indicates the presence of <usonic_dist> field, bit 1 indicates the presence of <voltage>, bit 2 indicates the presence of <temp>. | ||
Line 57: | Line 59: | ||
== Downlink Frame format == | == Downlink Frame format == | ||
+ | <span style="color:#FF0000">'''Note :''' Frame format of sensors delivered before 1st of November 2017 can be found [[NIS-UL UltraSonic Sensor - Frame Format v0.x|here]] </span> | ||
+ | <br><br> | ||
The sensor configuration contains the following fields: | The sensor configuration contains the following fields: | ||
Revision as of 09:14, 24 November 2017
Contents
1 General information
1.1 Overview
- LoRa™ WAN 1.0.2 EU Class A & C
- Activation by Personalization (ABP)
- Over-The-Air Activation (OTAA)
- SIGFOX™ ready
- Fully certified on major LoraWan & Sigfox networks
- Easy to use and deploy
- 3.6V / 2200mAh Primary battery Li-SOCl2 embedded
- Magnetic switch and LED to ease the installation
- RoHS conform / Pre-Certified ETSI EN 300-220 / RED compliance under certification
1.1.1 RF Performance
- TX Power 14 dBm (25 mW)
- RX Sensitivity -137 dBm
- Approx. 10 km range
- Integrated PCB antenna
1.1.2 Environment
- Operating temperature -40°C to +85°C
- Storage temperature 30°C recommended (to limit battery self-discharge)
- Rel. humidity 0% to 95% (not condensing)
1.1.3 Options
- External antenna
- SDK for your SW development purposes
- 10-30V external power supply
- Compatible with the NEMEUS PicoGateway for private networks
1.2 Installation
By using the internal antenna, the position of the sensor is critical.
Install your product as high as possible, and prefer unobstructed area (concrete and metal are the worst materials).
If you cannot fulfill these conditions, it is still possible to use an optional external antenna.
2 Mechanics
- Dimensions 60 x 95 x 85mm (109mm including fixing brackets)
- 96mm spacing between brackets
- IP 65
- Solid ABS & PC material
3 WARNING
This sensor is not designed for critical purposes. It should never be used in an application where a malfunction of the device could cause personal injury. Due to ultrasonic physics, we can not guarantee 100% reliability at close distances.
4 Ultrasonic sensor properties
Default configuration allows target detection until 6 meters.
Objects from 0cm to 20cm range are reported as 20cm.
The acoustic detection pattern has an angle of 7°. The geometry of the detection pattern depends mainly on the size, orientation, and acoustic properties of the target, but also on the atmospheric pressure, temperature and humidity.
Each sensor is factory calibrated to unify results between sensors.
5 Magnetic Switch Protocol description
5.1 Generic Magnetic Switch Protocol description
Nemeus sensors embed a magnetic switch and a green LED to implement a simple man to machine interface.
The LED blinks every second while the magnet is present.
If the magnet is present during 20 seconds, it triggers an hardware reset.
The 20 seconds range has been cut in 10 timeslots of 2 seconds, the actions performed for each timeslot (TSX) are the following:
- 0s <= TS1 < 2s: read current state, number of led blinks indicates the following states:
- 1 blink: standby mode
- 2 blinks: joint with LoRaWAN network only (Sigfox is disabled)
- 3 blinks: Sigfox enabled only (no LoRaWAN)
- 4 blinks: joint with LoRaWAN network and Sigfox is enabled
- 6 blinks: joining LoRaWAN network (no Sigfox)
- 8 blinks: joining LoRaWAN network and Sigfox is enabled
- 9 blinks: measures are ongoing but transmission is forbidden
- 2s <= TS2 < 4s: switch to normal mode (if not already in normal mode) or force one measure and one Tx (if already in normal mode)
- 4s <= TS3 < 6s: switch to standby mode, it is the default mode when the device is stored and not yet activated
- 6s <= TS4 < 8s: perform a warm reset, the device resets and goes back to its previous mode
- 8s <= TS5 < 10s: forbid transmission, the device still performs measures but never transmit them
- 10s <= TS6 < 12s: switch to test mode, the device suspends the measures and forbid transmission, then it switches to continuous Rx on a specific channel and wait for test mode commands, if nothing is received after 60 seconds then it goes back to its previous mode. During test mode the led blinks and the magnetic switch is disabled.
- 12s <= TS7 < 14s: no action
- 14s <= TS8 < 16s: no action
- 16s <= TS9 < 18s: no action
- 18s <= TS10 < 20s: no action
- 20s <= TSHw: hardware reset
When the magnet is removed, the LED blinks fast X times, X identifies the timeslot (1 to 10).
5.1.1 Standby mode
It is the default mode set in factory, the device does nothing and consumes few µA (consumption depends on the sensor type).
5.1.2 Normal mode
The first time the device switches to normal mode, it performs the join procedure with the LoRaWAN network.
Then it performs a first measure and transmits it to the network whatever the number of measures required to trigger a transmission.
Finally it performs measures according to the configured period and transmits them according to configured number of measures required to trigger a transmission.
5.1.3 Forbid transmission mode
In this mode the device performs measures according to the configured period but never transmits them to the LoRaWAN network. This mode is mainly used in R&D phase to tune the measure algorithm, it shouldn’t be used when the device is deployed.
5.1.4 Test mode
This mode is used to modify the device configuration over the air using a Nemeus tool, this tool must be in the vicinity of the device. A security key is used to authenticate the Nemeus tool and the device.
5.1.5 Warm reset
The warm reset restarts the device and put it in its previous state. For example, if the device was joining the network, it restarts its join procedure. If it was already joint and performing periodic measures then it transmits the first measure and restarts the periodic measures.
6 Radio frames description
6.1 Generic Application Protocol description
6.1.1 Nemeus uplink protocol
Nemeus uplink protocol is used to send sensor data to application server. The payload contains the following fields:
- <mask>: At least 1 byte containing a bit field identifying the fields included in the frame. The meaning of the mask is specific to the couple device/port. Thus, the application server knows the mask meaning according to the data profile linked to the couple device/port. The most significant bit of the <mask> is used to extend the mask on the next byte: 1 means not extended (mask is on 7 bits) and 0 means extended (mask is on 14 bits). When extended, the following byte can also be extended according to its most significant bit. When the <mask> field is on several bytes, it is encoded in little endian (LSB first). For example, a <mask> coded on 2 bytes like “00100001 11001100” will be on 14 bits: “10011000100001”. Each bit indicates the presence/absence of a field. When a field is present, it appears in the frame according to the bit position (beginning with the least significant bit).
- <field1>: first data field identified by the data profile linked to the couple device/port.
- …
- <fieldN>: last data field identified by the data profile linked to the couple device/port.
6.1.2 Nemeus downlink protocol
Nemeus downlink protocol is used to exchange commands between application servers (located in network infra or in configuration PC) and sensor embedded applications.
Application port is used to address an application (application ports are bound with LoRaWAN ports). Thus, the protocol consists in a binary payload exchanged on a port. The payload contains the following fields:
- <cmd>: 1 byte identifying an applicative command/response.
- <mask>: At least 1 byte containing a bit field identifying the fields included in the frame. See uplink protocol above for description.
- <field1>: first data field identified by the data profile linked to the couple device/port.
- …
- <fieldN>: last data field identified by the data profile linked to the couple device/port.
Most significant bit of <cmd> field specifies if response is expected by the server or not (commands of type “set” doesn’t require any answer, especially when radio interface is used).
<cmd> values are defined for each application port (e.g. <cmd> value 0x01 has a different meaning on port 1 than on port 2).
A response reuse the same <cmd> as the received command, except the most significant bit which is forced to 0 (because a response doesn’t expect any response). The response <mask> indicates which fields of the command have been actually processed.
When a parameter type size is more than one byte, it is encoded in little endian (LSB first).
Downlink command may be received either from network application server or from PC configuration tool through AT command.
The generic application AT command is used:
AT+GA=DIND,<port>,<hexpayload>.
6.2 Uplink data Frame format
Note : Frame format of sensors delivered before 1st of November 2017 can be found here
The uplink payload contains multiple fields:
<mask>: bit field on 1 byte indicating the presence of other fields. Bit 7 is always to 1 because the mask is never extended on next byte. Least significant bit (bit 0) indicates the presence of <usonic_dist> field, bit 1 indicates the presence of <voltage>, bit 2 indicates the presence of <temp>.
Whatever the <mask> value, the field <nb_meas> follows it and applies to all measures. Thus, the frame starts with <mask><nb_meas>.
- <nb_meas>: 1 byte containing the number of measures which follow.
if (mask.bit0 == 1) :
- <usonic_dist>: 2*<nb_meas> bytes containing the distances measured by the ultrasonic sensor in centimeters (1 to 600 cm in big endian).
if (mask.bit1 == 1) :
- <voltage>: 2*<nb_meas> bytes containing the voltages measured by the sensor in millivolts (in big endian).
if (mask.bit2 == 1) :
- <temp>: 1*<nb_meas> bytes containing the measured temperatures (signed integer)
Thus the uplink frame format is <mask><nb_meas><usonic_dist1>...<usonic_distN><voltage1>...<voltageN><temp1>...<tempN>
Default <mask> value is 0x85 which means that the default frame is <mask><nb_meas><usonic_dist1>...<usonic_distN><temp1>...<tempN> (the voltage is not present)
Some examples (in hexadecimal):
- “8502009700981f19”: the frame indicates two measurements of 151cm and 152cm followed by two temperatures of 31°C and 25°C.
- “810100a0”: the frame indicates a single measurement of 160cm without temperature.
- “84011e”: the frame indicates one temperature of 30°C.
- “fd02009c009c1c19xxxxxxxxxxxx”: the frame indicates two measurements of 156cm and 156cm with two temperatures of 28°C and 25°C followed by private data (used for debug).
6.3 Downlink Frame format
Note : Frame format of sensors delivered before 1st of November 2017 can be found here
The sensor configuration contains the following fields:
- <up_frame_mask>: the mask identifying the different fields present in uplink frames (possible values are described in “Uplink data Frame format” section)
- <nb_meas_for_tx>: the number of measures required to trigger a transmission (possible values are [1..8]
- <meas_period>: the period of the measures in <perdiod_unit> seconds(possible values are [600..65535]
- <period_unit>: the unit of <meas_period> in seconds, the resulting period is <meas_perios>*<period_unit> seconds
It is possible to change the sensor configuration using the Nemeus downlink protocol. The downlink frame must be sent on the MS006 LoRaWAN port (8).
The downlink frame has the following format:
<cmd>: 1 byte containing WRITE_CFG_CMD=0x02
<mask>: bit field on 1 byte indicating the presence of other fields. Most significant bit (bit7) is always to 1 because the mask is never extended on next byte. Least significant bit (bit0) indicates the presence of <up_frame_mask> field, bit1 indicates the presence of <nb_meas_for_tx>, bit2 indicates the presence of <meas_period> and bit3 indicates the presence of <period_unit>
If (mask.bit0 == 1):
- <up_frame_mask>: 1 byte containing the uplink frame mask
If (mask.bit1 == 1):
- <nb_meas_for_tx>: 1 byte containing the number of measures required to trigger a transmission
If (mask.bit2 == 1):
- <meas_period>: 2 bytes in little endian (LSB first) containing the period of measures in seconds
If (mask.bit3 == 1):
- <period_unit>: 1 byte containing the unit of <meas_period> in seconds (default value is 1 second)
Thus the downlink frame format is <cmd><mask><up_frame_mask><nb_meas_for_tx><meas_period><period_unit>.
Some examples in hexadecimal:
- “028181”: set the <up_frame_mask> to 0x81 => the next uplink frames will include the <usonic_dist> field only (no <voltage> field and no <temp> field)
- “028E04605401”: set <nb_meas_for_tx> to 4, <meas_period> to 21600*<period_unit> seconds and <period_unit> to 1 second => one measure every 6 hours and one transmission every 4 measures (every day). Each uplink frame will include 4 measures
6.4 Power consumption
Please find below a tool to calculate power consumption vs number of measures and transmissions.